275nm UVC LED Germicidal
Description
Basic Info.
Model NO. | GG-UVC265 |
Type | Deep UV LED |
Wire Material | Pure Gold |
Base Material | Aluminum Nitride |
Chip Brand | UVC LED Light |
Max Current | 100mA |
Max Radiant Power | 8-10MW |
Warranty | 3 Years |
Forward Current | 40mA |
Radiant Power | 2-4MW |
Wavelength | 270-280nm |
Voltage | 5-7V |
Power | 0.25 |
Transport Package | 1000PCS/Bag |
Specification | 3535 led |
Trademark | GM |
Origin | China. Shenzhen |
HS Code | 8541401000 |
Production Capacity | 360000/Month |
Product Description
275nm UVC LED GERMICIDALProduct Application:
Disinfection, Phototherapy, Fluorescent Spectroscopy, Sensor Light, Bio-Analysis / Detection, Counterfeit Detectors, etc
Chip Brand | LG or Nichia or Epileds | Forward Current: | 40mA or max to 100mA |
Base Material | High Thermal conductivity Aluminum Nitride Base | Forward Voltage | 5-7v |
Wire Brand | Germany Heraeus Gold wire | Dimension | 3.5x3.5 x1.35mm |
Radiant Power | 2-4mw @40mA or 7-10mw @100mA | View angle | 120 degree |
Working Temperature | -30ºC -- + 60ºC |
Certificates | LM-80. CE. Rohs,Fcc . |
Warranty | 2000hrs or 1 year |
Delivery Time | Within 7 workdays when Qty<100.000pcs |
Key Words | uvc led sterilizer box |
Product Dimension:
Absolute Maximum Rating:
*Operating the LED beyond the listed maximum ratings may affect device reliability and cause permanent damage. These or any other conditions beyond those indicated under recommended operating conditions are not implied. The exposure to the absolute maximum rated conditions may affect device reliability. *The LEDs are not designed to be driven in reverse bias.
Electro-Optical Characteristics
UVC LED Microbiological test report:
Several questions about UVC LED disinfection and UVC wavelength
Can UVC help prevent ******** transmission by reducing contamination?
Based on existing evidence, we believe so. Here's why:
UVC light has been used extensively for more than 40 years in disinfecting drinking water, waste water, air, pharmaceutical products, and surfaces against a whole suite of human pathogens (Fluence UV Dose Required review IUVA). All bacteria and ******** tested to date (many hundreds over the years, including other********) respond to UV disinfection. Some organisms are more susceptible to UVC disinfection than others, but all tested so far do respond at the appropriate doses.
What is the "sterilizing range" of UV?
According to the International Ultraviolet Association, "the ultraviolet spectrum (the 'sterilization' region) that is important for water and air disinfection is the range absorbed by DNA (RNA in some ********). This sterilization range is about 200-300nm."
It is known that the bactericidal range extends above 280 nm, and it is now generally considered to extend to 300 nm, however this may also change with more research. Scientists have shown that ultraviolet light with a wavelength between 280nm and 300nm can be used for disinfection and sterilization.
What is the optimal wavelength for disinfection?
There is a misunderstanding that 254nm is the optimal wavelength for disinfection because the peak wavelength of a low-pressure mercury lamp (determined solely by the physics of the lamp) is 253.7nm. The wavelength of 265 nm is generally considered to be optimal because this wavelength is the peak of the DNA absorption curve. However, a range of wavelengths have disinfection and sterilization effects.
Ultraviolet mercury lamps were once considered the best choice for disinfection and sterilization. Why is this?
Historically, mercury lamps have been the only option for disinfection and sterilization. With the advancement of UV LED technology, there are new options because LEDs are smaller, more powerful, non-toxic, longer life, more energy efficient, and allow more switching times. This makes the solution smaller, battery-powered, more portable, and capable of instant full-light output.
What is the difference in wavelength characteristics between UVC LEDs and mercury lamps?
Low-pressure mercury lamps emit nearly monochromatic light with a wavelength of 253.7 nm. Low-pressure mercury lamps (fluorescent tubes) and high-pressure mercury lamps are also used for disinfection and sterilization. These lamps have a broader spectral distribution, including wavelengths used for sterilization. UVC LEDs can be focused on a narrow range of specific wavelengths, which allows the solution to be tailored to specific application needs.
Does the peak absorption wavelength of DNA vary by bacteria?
Yes. Different types of peak absorption wavelengths are indeed different, but most of them are around 265nm.
Can a single wavelength eliminate all bacteria?
Yes, a single wavelength can be used. However, bacteria have different optimal absorption wavelengths.
How is the bactericidal effect determined?
Generally, power intensity, wavelength, and duration of irradiation are used to determine the bactericidal effect. For example, in water, there may be multiple bacteria with different optimal absorption wavelengths. For any given wavelength of germicidal UV, the power and time of irradiation need to be calculated to achieve the desired level of disinfection.
Are UVC disinfection devices safe?
Like any disinfection system, UVC devices must be used properly to be safe.) They all produce varying amounts of UVC light in wavelengths of 200nm-280nm. This UVC light is much "stronger" than normal sunlight, and can cause a severe sunburn-like reaction to your skin, and similarly, could damage the retina of your eye, if exposed. Some devices also produce ozone as part of their cycle, others produce light and heat like an arc welder, others move during their cycles. Hence, general machine-human safety needs to be considered with all disinfection devices, and these considerations should be addressed in the operations manual, in the user training, and appropriate safety compliance.
Are there performance standards and UVC validation protocols for UV disinfection devices?
Given the wide array of UVC devices marketed for disinfection of air, water and solid surfaces, the lack of uniform performance standards and the highly variable degree of research, development and validation testing that is performed on different devices, the IUVA urges consumers to exercise caution when selecting equipment and look for evidence of third party testing as well as certification of device materials and electrical components by well-known organizations such as UL, CSA, DVGW-OVGW or other international requirements as applicable.
For UVC devices designed to inactivate air and solid surfaces in the healthcare industry, members of IUVA are working diligently with other national standards organizations in the lighting and healthcare industry to develop disinfection testing standards[x]. The goal is to develop guidance that will help healthcare providers world-wide choose the best possible technologies for their institutions to use in the fight against multiple drug resistant organisms and other pathogens
Company Introduction:
Shenzhen Guangmai Electronics Co.,Ltd is a High-Tech firm founded in 2005 with registered capital 5 million USD. We specialize in the development of LED products, owning a experienced and skilled engineer team team to meet customers' demand.currently we have total staff member of 120 people. We are the first choice for lighting project in LED.
With many years of led technology and rigorous management,we received the praise and trust from clients.Our philosophy is " focus on technology,provide the best LED" ,making good quality products and bringing more value to our clients.We are your honesty partner in the world and make a contribution to the green light industry.GMKJ is fighting to achieve the goal of "To be the best LED lighting supplier" .
Prev: UVB LED 5MW 18MW 30MW 60MW Ultraviolet 308nm 300nm 315nm 310nm Peak Wavelength UVC 3535 LED UV 6V
Our Contact